Q16-S & Q32-S
SD Video & Embedded Audio Routers
The Q16-S and Q32-S series are standard definition digital video and embedded audio routers.
Configuration: The modular design of the Q16-S and Q32-S routers give them a high degree of flexibility, allowing them to be easily configured in square or non-square sizes.
The Q16-S are housed in a 1RU frame and switches 16 sources to 16 destinations. The input stage of the Q16-S is fixed at 16 while the output stage is fully configurable. Up to 16 individual output SIMMs can be added to the output stage of the router at anytime.
The Q32-S is housed in a 2RU frame and can switch up to 32 sources to 32 destinations. The input stage of the Q32-S is initially fixed at 16 with the ability to add a further 16 input SIMMs to the router at anytime. The output stage is fully configurable with up to 32 individual output SIMMs being added to the output stage of the router at anytime.
Control: Both the Q16-S and the Q32-S router include, as standard, an internal Frame Controller module which supports a single Q-Link and Serial port on the rear of the router. The optional internal CI module can be fitted to the Q32-S to increase the number of Q-Link and Serial ports. This option is not available for the Q16-S.
The Q16-S and Q32-S have a number of control options, they are:
Local Control Panels: The CP-1600A-LP, can be fitted to the Q16-S (up to a maximum matrix size of 16x8). This option is not available for the Q32-S.
Passive Remote Control Panels: The CP-1601A-P and CP-1604-P passive remote control panels can be fitted to the Q16-S and Q32-S router via a PI-1604 or PI-1608 parallel to interface.
Remote Control Panel: Any panel(s) from the entire range of Quartz remote control panels can be used with the Q16-S and Q32-S router connected via Q-Link.
External third party control: The Q16-S and Q32-S router can be remotely controlled via an external third party control device, such as an automation system, when connected to the routers serial port.
Expansion: The output stage of the Q16-S and the input and output stage of the Q32-S can expanded at any time by adding additional SIMMs. They can not be expanded beyond their frame size.
Power Supply: The power supplies for the Q16-S and the Q32-S are internal. The 2RU Q32-S frame can be fitted with an optional redundant power supply with separate AC power inlet and alarm output. This option is not available for the Q16-S.
Features
|
|
Specifications
| Configuration | |
|---|---|
| Inputs | |
| Q16 | Fixed at 16 |
| Q32 | Selectable, 16 or 32 |
| Outputs | |
| Q16 | Selectable, in blocks of one |
| Q32 | Selectable, in blocks of one |
| Video Inputs | |
|---|---|
| Signal Level | 800mV p-p nominal |
| Impedance | 75Ω terminating |
| Return Loss | 15dB, 16dB typical (5 - 270MHz) |
| Cable equalization | |
| Reclocking | |
| Belden 8281, BBC PSF1/2 | 250m min, 300m (980 ft) typical @ 270MHz |
| BBC PSF1/3 | 150m min, 200m (650 ft) typical @ 270MHz |
| Non-Reclocking | Total Input plus Output Cable length supported up to 270MHz |
| Belden 8281, BBC PSF1/2 | 100m min, 200m (650 ft) typical @ 270MHz |
| BBC PSF1/3 | 60m min, 120m (390 ft) typical @ 270MHz |
| Connectors | BNC |
| Video Outputs | |
|---|---|
| Signal Level | 800mV p-p ±10% |
| Impedance | 75Ω terminating |
| Return Loss | 15dB (5 - 270MHz) |
| DC offset | 0 ± 0.5V |
| Connectors | BNC per IEC 61169-8 Annex A |
| Signal Path | |
|---|---|
| Rise/fall times | 0.6 to 0.9ns |
| Path length | 12ns, typical |
| Output jitter | 0.2UI p-p with < 300m input cable |
| Control | |
|---|---|
| Q-Link to remote panels | 1 as standard (additional 3 Q-links optional) |
| Interconnect | 75Ω video cable 500m (1600 ft) max. length |
| Connector | BNC per IEC 61169-8 Annex A |
| Serial RS232/422 | 1 as standard (additional port optional) |
| Connector | D9 female |
| Switching Reference | |
|---|---|
| Reference inputs | Analogue 625 or 525 black |
| Signal level | 1V p-p ±3dB or 1V - 4V pulses |
| Impedance | 75Ω (loop through) |
| Switching Line | Lines 6/319 (625) Lines 10/273 (525) |
| Electrical | |
|---|---|
| Supply | Auto ranging 100-240V AC, 50/60Hz |
| Power consumption | 25 Watts (Q16) or 50 Watts (Q32) |
| Dual PSU | Optional with alarm output (Q32 only) |
| Physical | |
|---|---|
| Height | Q16: 1RU (1.75" nom.), 44mm Q32: 2RU, (3.5" nom.) 88mm |
| Width | 19" (483mm) |
| Depth | 19" (483mm) |
| Weight | Q16: 5.2kg (11.3lb) Q32: 6.6kg (14.5lb) |
| Operating Temperature | 0 - 40°C |
| Ventilation | Fan cooled. Air intake at front, exhaust at the sides. |
Ordering Information
| Notes | • Replace xx with the number of inputs required (16 or 32) |
|---|---|
| • Replace nn with the number of outputs required | |
| • For reclocking outputs, order appropriate +R option | |
| • For other configurations contact factory |
| Q16-16nnS | 16 Input SDI router with non-reclocking outputs (blocks of 4) |
|---|---|
| Q32-xxnnS | 16 or 32 Input SDI router with non-reclocking outputs (blocks of 4) |
| Ordering Options | |
|---|---|
| Notes | • For mixed frames, order reclocking with router and non-reclocking separately |
| +2PS | Redundant Power Supply for Q32 only |
|---|---|
| +R4 | Reclocking option for Q16-1604 & Q32-3204 |
| +R8 | Reclocking option for Q16-1608 only |
| +R16 | Reclocking option for Q16-1616 & Q32-3216 |
| +R32 | Reclocking option for Q32-3232 only |
| Accessories | |
|---|---|
| Notes | • CI-0004 Accessories are only available for Q32 frames |
| CI-0001 | Sub-module that enables a second RS232/422 serial port |
|---|---|
| CI-0004 | Multi Q-Link Card - Fits inside frame to add up to three Q-Link ports and one RS232/422 port (Q32-S routers only) |
| AK-0002 | Rear frame support kit for Q16, strongly recommended for mobile applications |
| Control Panels | Enhance the function and usability of this router with a variety of control panels |


Router Control Panels